Why the Shaw Ultra High Capacitance Aluminium Oxide Sensor Matters

By September 17, 2026October 13th, 2026News

Read Why Our Ultra High Capacitance Aluminium Oxide Sensor is Designed for Long Term Stability

A dewpoint instrument is only as good as its sensor. If the sensor drifts, responds slowly or degrades in demanding conditions, even the best electronics cannot deliver a trustworthy reading.

Shaw’s ultra high capacitance aluminium oxide sensor delivers stable, responsive trace moisture measurement across demanding industrial applications. Its performance stems from how Shaw manufactures the sensor, especially the layers and pores that interact with water vapour.

What makes the Shaw sensor different?

Capacitance based aluminium oxide sensing is a well established method for measuring trace moisture. However, not all sensors using this technology deliver the same long term performance.

At the heart of the Shaw sensor lies the Base Insulating Layer. This layer provides the foundation for the moisture sensitive oxide above it and its structure, thickness and consistency shape how the sensor responds over time.

Specifically, Shaw’s manufacturing process controls the formation of this layer and the pore geometry within the sensing structure. This precision, in turn, helps the sensor maintain a predictable response as moisture levels change.

Reducing dry end drift

In continuous low moisture applications, such as compressed air downstream of a desiccant dryer, sensor stability matters. For instance, a sensor with an uneven or porous Base Layer can retain moisture in secondary capillary paths. Over time, that moisture may release slowly, contributing to calibration changes and a progressively inaccurate dry end reading.

Additionally, another possible consequence is a flat spot response, where the sensor may react slowly when moisture levels increase again after a prolonged period of dry operation.

This becomes a serious problem when the measurement must identify moisture breakthrough early: a falsely reassuring dry reading may delay corrective action while the process is already becoming wetter.

To address this, Shaw manufactures the sensor with a precisely formed and evenly constructed Base Layer. This design minimises the secondary moisture storage that can drive dry end drift and slow recovery.

Selective measurement of water vapour

Many industrial gases contain components that could affect a moisture measurement. Hydrogen applications, for example, require careful consideration of both the gas being measured and the water vapour present within it.

Here, the Shaw sensor’s controlled pore geometry provides selectivity for water vapour. Hydrogen molecules are small enough to enter the pores, but their low dielectric constant produces little capacitance change. Conversely, larger polar molecules, such as methanol, may have a stronger electrical effect but can be restricted by their physical size.

Water vapour, meanwhile, occupies the important middle ground: it is small enough to enter the pores and sufficiently polar to produce a measurable capacitance change.

As a result, the sensor responds primarily to moisture rather than producing a combined response to every component in the gas stream.

AutoCal supports long term accuracy

Beyond sensor design, Shaw’s AutoCal function provides a practical way to check and adjust the instrument in the field.

The sensor features a predictable saturation point at the upper end of its calibrated range. When exposed to a gas wetter than that point, ambient air for example, the sensor reaches a repeatable condition that serves as a reference for a span check.

From there, the instrument can adjust to that known point, helping compensate for gradual sensitivity changes caused by contamination or extended operation.

For many applications, users perform this check periodically, typically every two to three months, in line with the instrument’s operating instructions and the user’s quality procedures.

Designed for demanding applications

Taken together, the SHAW ultra high capacitance aluminium oxide sensor delivers:

  • Shaw brand accurate held hygrometer
    Fast and predictable response during both drying and wetting conditions
  • Shaw brand accurate held hygrometer
    High selectivity for water vapour
  • Shaw brand accurate held hygrometer
    A measurement range from 0.001 ppm to 0.2% by volume
  • Shaw brand accurate held hygrometer
    Dewpoint measurement from approximately −100 °C to +20 °C, depending on instrument configuration
  • Shaw brand accurate held hygrometer
    Flow independent measurement
  • Shaw brand accurate held hygrometer
    Low hysteresis and low temperature coefficients
  • Shaw brand accurate held hygrometer
    Operation across a wide range of temperature and pressure conditions
  • Shaw brand accurate held hygrometer
    Minimal routine maintenance
  • Shaw brand accurate held hygrometer
    Compatibility with hazardous area applications where the relevant instrument configuration is certified to ATEX and IECEx requirements

Calibration you can trust

Of course, sensor design is only part of measurement confidence — the calibration behind the instrument matters just as much.

To that end, every Shaw hygrometer is shipped with a Certificate of Calibration. Shaw’s calibration process is traceable to national and international humidity standards at the UK’s National Physical Laboratory (NPL) through the company’s absolute primary reference hygrometers.

In addition, Shaw’s quality management system is independently certified to ISO 9001:2015.

Together, stable sensor construction and traceable calibration give confidence that the instrument will continue to deliver reliable measurements, not only at commissioning but throughout its service life.

The sensor is the real differentiator

Displays, outputs and software all contribute to the usability of a moisture instrument. However, they depend on one fundamental requirement: the sensor must accurately reflect the moisture content of the gas.

Ultimately, Shaw has designed and manufactured dewpoint and trace moisture measurement equipment since 1960. Its ultra high capacitance aluminium oxide sensor delivers stable, selective and responsive measurement across industrial applications, including demanding low moisture and hazardous area environments.

To find the right Shaw sensor and instrument configuration for your application, contact the Shaw Moisture Meters applications engineering team.

Want to understand the technology in more detail?

Available soon – our technical guide, how SHAW manufactures its ultra high capacitance aluminium oxide sensor, how its Base Layer supports long term stability and how AutoCal helps maintain measurement confidence in the field.